Legionella: Health Effects, Occurrence and Sampling

Jackson Kung'u

Health effects of Legionella

In 1976, in Philadelphia, USA, over 200 attendees of the US-American Legion, developed pneumonia. The disease was later called “Legionnaires’ disease”. The causative agent, a Gram-negative bacterium, was named Legionella pneumophila. Legionella pneumophila causes 85-90% of all cases of Legionella infections (legionellosis). There are over 40 species of Legionella.

Legionella pneumophila can cause very severe infection of the respiratory system. However, Legionnaires’ disease epidemics are rare but the disease is fatal if untreated. The disease may develop within 2 to 13 days (average 5-6 days).

Another form of legionellosis is Pontiac fever, named after an outbreak in 1968 in Pontiac, USA. This form of disease, caused by a number of Legionella species, is milder than Legionnaires’ disease. Pontiac fever develops within 48 to 72 hours and the illness may clear in 2-5 days. No fatal cases have been reported in relation to Pontiac fever. This disease mainly appears as epidemics. Pontiac fever is believed to be a reaction to inhaled Legionella antigens rather than an infection.

Disease transmission

There is no evidence for transmission of legionellosis from person to person or by ingestion. Legionella infection occurs when people inhale the bacterium via fine water droplets as aerosols from the environment. Indoor transmission of legionellosis has been reported via contaminated hot water supplies in hospitals, hotels and other public buildings, respiratory therapy equipment, jacuzzis, spas and air-humidifiers.

Occurrence

Legionella bacteria are part of the natural aquatic bacterial population of lakes and rivers. They are present in all types of fresh water, including tap water. Legionella multiply in water, using other microorganisms like bacteria, algae and protozoa. Their concentration in fresh water is influenced mainly by the temperature. They are isolated more frequently and in higher concentrations from warm water (30 to 50 °C.). However, Legionella also survive at much lower temperatures indoors as well as outdoors. At temperatures above 60 °C Legionella can’t survive.

Sampling Of Legionella

Sampling of Legionella in indoor air or water on a routine basis is not recommended. However, sampling is recommended to:

  • determine the source of outbreaks of legionellosis
  • check the effectiveness of maintenance practices and control measures for hot water supplies and humidified ventilation systems
  • guarantee the safe use of hot water supplies and humidified ventilation systems.

When investigating the water services within a building for Legionella, the condition of pipes, the joining methods used, the presence of lagging, sources of heat, and the standard of protection afforded tanks should be noted, as well as disconnected fittings, ‘dead-ends’, and cross-connections with other services.Water Sampling
Water samples should be collected in sterile autoclavable plastic containers. The samples should be taken from:

  • the incoming supply;
  • tanks;
  • an outlet close to, but downstream of, each tank;
  • the distant point of each service;
  • the water entering and leaving any fitting under particular suspicion.

Surface Sampling
Using swabs, surface samples should be taken from shower heads, pipes and taps. Also, sludge, slime or sediments within building water services or humidifiers can also be collected, particularly where accumulation occurs.

Sample Handling and Storage
Samples should be stored at room temperature (20 ± 5 °C.) in the dark and should be processed within 2 days. That means the samples should be sent to the laboratory within 24 hours. It is also important to confirm with the lab that they have the necessary media before sampling is done.

Air sampling
The presence of Legionella in indoor air can be investigated using Reuter Centrifugal Sampler (RCS) or the Andersen sampler. Regardless of the sampler used, the recommended sampling agar at present is BCYE-agar.

References

  1. Flannigan, B., R.A. Samson, and J.D. Miller (Editors). Microorganisms in home and indoor work environments: diversity, health impacts, investigation and control. 2001. London, UK: Taylor & Francis (ISBN: 0-415-26800-1).
  2. Wanner, H-U, AP Verhoeff, A Colombi, B Flannigan, S Gravesen, A Mouilleseux, A Nevalainen, J Papadakis, and K Seidel. 1993. Biological Particles in Indoor Environments. Indoor Air Quality and Its Impact On Man. Brussels: Commission of the European Communities. Report No. 12.

For more information on indoor bacteria, please visit http://www.moldbacteria.com/ or call 905-290-101.

Filed Under: Bacteria, Microbial Sampling, Water Testing Tagged With: algae, Bacteria, health risks, Legionella, legionellosis, legionnaires disease, pontiac fever, protozoa, sampling

How To Test For Mold And Bacteria In Carpets

Jackson Kung'u

Carpets serve as a reservoir for settled mold and bacteria spores, dust, lead, dust mite allergens and other chemical and biological contaminants. These contaminants, a major cause of respiratory problems, become airborne when the carpet is disturbed, for example during vacuum cleaning with an ordinary vacuum cleaning machine. The particle size of these contaminants is small enough to be inhaled deep into the lungs.

The best way to test for mold and bacteria in carpets is to collect dust and send it to a lab for culturing. Swabs could also be used but they may not work very well on some types of carpets.

For more information on how to test for mold and bacteria from carpets and other surfaces, please contact Mold & Bacteria Consulting Laboratories by phone at (905) 290-9101.

Filed Under: Bacteria, Fungi Tagged With: Bacteria, spores

Bacteria in the Water: Coliforms, Iron and Sulfur Bacteria

Jackson Kung'u

In the past we’ve discussed Legionnaires’ disease, which is a disease caused by a waterborne bacterium. In our September newsletter entitled, Bacteria in the Water: Coliforms, Iron and Sulfur Bacteria, we have discussed three types of waterborne bacteria: coliforms, which, although not usually harmful, can be a sign of other bacteria that are harmful; and iron and sulfur bacteria, which are seen as annoyances rather than a health threat. For more details read our Bacteria in Water: Coliforms, Iron and Sulfur Bacteria.

If interested in bacteria testing, visit the web page Testing For Bacteria or call 905-290-9101.

Filed Under: Bacteria, Water Testing Tagged With: coliform, fecal coliforms, iron bacteria, sulfur bacteria

What is the Difference between Moulds and Bacteria?

Jackson Kung'u

Recently one of our website visitors wanted to know the difference between moulds and bacteria.

Moulds and bacteria are very different organisms. They are genetically unrelated. Moulds are larger, complex and grow as long, multi‑celled filaments (hyphae). Those filaments can aggregate to form larger masses (referred to as mycelia) visible to unaided eye. That is why we can see mould growth, for example, on a wall surface. Bacteria are smaller, single-celled and less complex. Requirements for growth and the means of reproduction for moulds and bacteria differ in many aspects.

Do you have a mould problem? Call (905)290-9101.

Filed Under: Bacteria, Fungi Tagged With: Bacteria, molds, mould, moulds

  • « Previous Page
  • 1
  • 2
  • 3
  • 4

What’s New?

  • Indoor Air Quality Testing in Toronto, Ontario
  • Air Quality Testing in Vancouver, BC
  • Mold Testing in Toronto, Ontario
  • Mold Testing in Vancouver, BC
  • Salmonella food poisoning and symptoms
June 2025
S M T W T F S
1234567
891011121314
15161718192021
22232425262728
2930  
« Jun    

Salmonella food poisoning and symptoms

Salmonella food poisoning has been a growing concern in recent news. It has frequently lead to recalls of beef, salads and organic products and, even peanut butter products. Salmonella food poisoning occurs when one eats raw or undercooked foods such meat, poultry, eggs or egg products. Properly cooked food can get contaminated with Salmonella if […]

Legionella pneumophila – Guidelines for Laboratory Interpretation

Legionella pneumophila is a Gram negative, aerobic bacteria that is characterized as an opportunistic pathogen. It is the cause of Legionnaires’ Disease, a severe form of pneumonia and, it is the cause of Pontiac fever, a non-pneumonic form of L. pneumophila infection. Legionella spp.’s mode of transmission is through aerosols or aspiration of contaminated water. The Public Health […]

The Indoor Mold Is An Early Warning Device

The mold (or mould, in the Queen’s English) has been the victim of a bad press. Mention the word and it conjures up an image of something rotting or in the process of decomposition. And yet, were it not for the mold that inspired the discovery of penicillin millions of lives would have been lost. […]